No software included. A few searches on the internet suggested copying EEPROMs or analyzing them. Concord 4 Installation Manual Specifications Power Requirements: Class 2, 16.5 VAC, 40 VA, 60 Hz (part no. For multiple-partition systems, we suggest a user manual for each partition. For Concord 4 systems, press 030 nnn 2, where nnn is the user number (000 to 229). Used it to read the installer code on a concord 4 alarm. 3. *The 24CXX programmer support XP, VISTA, WIN7 operating system. 3. Disclaimer: Use this process at your own list. After following the YouTube video above, I was able to get the application to work in English and show “Connected”. Concord 4 system - bricked after cancelled monitoring? That’s a bit scary IMO. 60- 680). If your module is 4G and unregistered, it […] Simply powering it down does nothing and shorting the chip's leads may (will) destroy it. I only performed a "read" across the entire EEPROM. The EEPROM reader that I purchased is a “SMAKN® USB Port 24CXX EEPROM Programmer Reader Writer to 24C1024 for XP VISTA WIN7” that I picked up from Amazon for roughly $10. To test my theory, I reinstalled the EEPROM into the surrogate system and changed it. Using the USB interface, can be directly plugged into the USB port on a computer chip can be programmed and read the complete work. Share - Concord 4 Installer Code Recovery EEPROM. Youtube user Kris Kasprzak has a how-to vid with a software/driver link that works. May 24, 2012 I need help programming my GE Concord 4 system with alphanumeric keypad. One of the more frustrating things for me is when someone, or some company, attempts to control me. No documentation , but was able to find some youtube video. *Can program the chip directly to the back of the package. Dimensions: 20mm X 55mm. *Programmer support hot-swapping, that is the case of uninterruptible power programmer can be removed or placed on the chip. Ultimately, I tried both possible positions on the other end of the socket. With PIN 1 in the middle, the chip was instantly VERY hot (and I assumed I had ruined it). My wife an I bought a house with an alarm system, and with all the excitement of moving in and owning our first home we took the path of least resistance and continued alarm monitoring with the original monitoring company. Electronic Home Security Systems, Alarms and Devices - Concord 4 constant Phone Test Failure - I am attempting to turn off Phone Testing, since this panel is … It worked for me, but I practiced the process on a separate alarm panel that had no value. Your recently viewed items and featured recommendations, Select the department you want to search in, No Import Fees Deposit & $7.78 Shipping to Singapore. Note that if you currently have service with another dealer, you won’t be able to activate service until that module is no longer linked to an active Alarm.com account. The software referred to in the other comment is flagged by Norton as unsafe and auto deleted. Enter programming menu by pressing 9 + System Menu Code. What’s Your Biggest Professional Challenge? The youtube video is for a different device. Concord ® 4 is a full-featured security system for residential and commercial intrusion as well as residential fire detection that complies with false alarm standards. 60-681) OR 12 VDC, 7Ah (part no. Press B button (down arrow to right of LCD display) until display reads User Codes, then press #. // There is an easy way to find the Dealer Code and Installer code: carefully remove the 8-pin EEPROM from the board, and I can help to read out the codes from the eeprom. This may or may does not reflect the position of past, present or future employers. YouTube — USB EEPROM Programmer and CH341A **DOWNLOAD LINKS. To turn remote access off, press 1, #. This aligned with what Kris mentioned in the video but did not seem to work wit my MIC24LC64. Service manuals, schematics, eproms for electrical technicians. Programmer supports the chip: *AT24C02 AT24C04 AT24C08 AT24C16 AT24C32 AT24C64 AT24C128 AT24C256 AT24C512 AT24C1024. That was exactly why I purchased the EEPROM programmer and tried to look for my known codes in my new Concord 4 panel that I programmed into the panel. As the rest say, it works, is entirely undocumented as it comes from Amazon, relies on the YouTube video, and the chip orientation does not correspond with either the video or the diagram on the board itself. It is cheap and also lacking documentation and software. Reads the dealer, installer, and master code from the EEPROM on Concord 4 security panels. In my case, I tried four different positions to put EEPROM into the programmer reader to find the correct one. It also analyzes reviews to verify trustworthiness. In the questions there is a recommendation to search youtube for drivers and software. Concord 4 Installer Code Recovery EEPROM. The primary goal included eliminating the dependence on a landline and getting the flexibility to do reconfigurations myself. After I turned it around, placing my chip’s PIN 1 (note the notch in one end of the chip–the end with pin 1)  in the socket’s PIN 16, I was able to read data it with the CH341 application. There was a problem completing your request. The system will NOT let me enter programming mode through 8+installer-code+0+0. In my case, I tried four different positions to put EEPROM into the programmer reader to find the correct one. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. I’m wondering what my options are for integrating it with a ST2. However, I was able to retrieve them by accessing the chip through an EEPROM programmer. Electronic Home Security Systems, Alarms and Devices - Concord 4 - no master codes SOLVED - Like many of you, I recently purchased a home with a Concord alarm system that had been disconnected (unmonit Package list: *1x EEPROM Programmer. It works! For me, the biggest challenge was getting an EEPROM reader working with my computer. I fo. To turn remote access on, press 2, #. Not knowing what to look for, I had preprogrammed a series of numbers as the installer code on a test unit. Concord 4 Series Security Systems Part Numbers: 600-1021-95R 600-1022-95R 600-1040 600-1042 www.gesecurity.com. The EEPROM reader that I purchased is a “SMAKN® USB Port 24CXX EEPROM Programmer Reader Writer to 24C1024 for XP VISTA WIN7” that I picked up from Amazon for roughly $10. This memory chip sits in a socket located on the alarm panel circuit board where shown (1rst image below). Unfortunately, none of those worked for my system and a call to my current alarm service company was met with, “We don’t provide those, we want to protect you from, making accidental changes.” They eventually agreed to try to change the code to another value  and called me back a few times. We work hard to protect your security and privacy. Upon investigation, I found that my alarm system was a bit challenging to reset the installer code. ... To open downloaded files you need acrobat reader or similar pdf reader program. I was unsure whether the manufacturer used an ASCII translation or some other method of encoding the number sequence. One of these items ships sooner than the other. Please make sure that you are posting in the form of a question. KKmoon EZP2019 High Speed USB SPI Programmer Better than EZP2010 EZP2013 Support 32... OBDSTAR X100 PRO Full Version Programmer with EEPROM Adapter. Display will read Reg Code 01 or Code 000. One important caveat on the youtube video: With this particular reader, the chip orientation shown in the software is correct. Reviewed in the United States on March 14, 2017. *1x DIP to Chip Block. In order to navigate out of this carousel please use your heading shortcut key to navigate to the next or previous heading. Your question might be answered by sellers, manufacturers, or customers who bought this product. Testing the installer code by entering ‘8 – CODE – 00’ revealed that I could now access the System Programming Menu. I can’t say for sure if the automation is only doing a direct bridge between RS485 and RS232 because I never bothered to try and verify the bits going into or coming out of the module on the panel side. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. I have the Dealer, Installer, System Master and Partition Master codes. So it might make sense to do this a computer that doesn’t have personal information and can be easily wiped. Press #. For Concord Express V4 systems, press 030 nn 2, where nn is the user number (00 to 15). As other buyer pointed out, you need to find software download links in Youtube. Using Your Concord 4 Panel Surety provides service for all Alarm.com compatible alarm systems, including the Concord 4. Display will read Regular User Codes . It works on the recent versions but I am not familiar with the early models so they may have this data stored in a different portion of the array. Key Switch style transition B *** Press B until Displays TRANSISTION. - master916/Concord-4-code-readouts-using-Arduino This cost less than 10% of what the installer would have charged for a fee to change the code. View all posts by Paul Stewart, CCIE 26009 (Security). Read these instructions and all related documentation entirely before installing or Cellular modules enable the Concord 4 to communicate signals wirelessly over either LTE or GSM/GPRS cellular networks. However, there is a great satisfaction for me when I learn something from the task at hand. I do think it is also worth mentioning that this code can be used to arm and disarm a system. Prime members enjoy FREE Delivery and exclusive access to music, movies, TV shows, original audio series, and Kindle books. GE Concord 4 Quick User Guide Page 4 To Delete a User Access Code: 1. USB Programmer Module CH341A Series Burner Chip 24 EEPROM BIOS LCD Writer 25 SPI Fl... Flashcat USB Memory Programmer BIOS MSI EEPROM NAND SPI JTAG I2C Serial (Includes S... XLX SOP8 to DIP8 Test Burn Clip Motherboard BIOS chip 8 pin Wide and Narrow Body Un... Amcrest FTDI USB Baofeng Programing Cable for Baofeng Radios– and Authentic FTDI Ch... Chironal 2 Set SOIC8 SOP8 Welding Wire + Board Test Clip for EEPROM 93CXX/25CXX/24C... To calculate the overall star rating and percentage breakdown by star, we don’t use a simple average. Sure enough, the change was represented properly when I re-read the output. Add a gift receipt for easy returns. Please try again. Concord 4 "Supervisory Zone 09 10" alert I apologize in advance for the profanity in the this article. Reviewed in the United States on December 4, 2018. There's a problem loading this menu right now. Display will read Reg Code 01 or Code 000. As I was looking for the software for this reader I was inundated with links to questionable sites. The installer had changed the codes. It works! Unable to add item to List. In other words, each number was encoded into a sequencial 4-bit nibble. Recently, I started looking into what moving my alarm system to a new monitoring service would entail. und that my unit used a MIC24LC64 chip and started researching ways to read it. I spent far more time reverse engineering my alarm system than the value if I’d paid the company to come out and reset it to a code they could provide to me. Feedback: We greatly appreciate your POSITIVE feedback. We don’t share your credit card details with third-party sellers, and we don’t sell your information to others. Searching the Internet yielded several options to try–1234, 9876, 4112 and 6112. There is a collection of different modules that perform different options as addons to the Concord that function over the SuperBus200. Works. GE Concord 4 Security System. This provides users with Alarm.com®’s secure wireless signaling and convenient functionality including real-time event notification, Web-based remote monitoring and other home system control capabilities. Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security can void the user’s authority to operate the equipment. In my case, I tried four different positions to put EEPROM into the programmer reader to find the correct one. Reviewed in the United States on March 10, 2016, worked for me. *PCB using high-quality glass plate, thickness 1.6mm. Hello student, the topic for today in the use of the English language is the 24 rules of concord which means an agreement between sentence elements in grammar. Sold by Gikfun_Official_Store and ships from Amazon Fulfillment. This shopping feature will continue to load items when the Enter key is pressed. It works! Please do NOT leave negative feedback without asking for help. The GE Concord 4 is a panel that has become a favorite among do-it-yourselfers and pro’s alike, and for good reason. GE Concord 4 Quick User Guide Page 4 To Delete a User Access Code: 1. Do this::NO NO NO: Watch what you are doing with the chip! My first recommendation is watching this video from Yo. In the video, Kris calls into question the orientation of the chip. Our aim is to provide Top Level Customer Service, so we will try our best to solve any problem.Thank you very much! ... To open downloaded files you need acrobat reader or similar pdf reader program. I reinserted the chip into the panel and powered it back up. make sure you have the chip plugged in the right way and use a 32bit OS, Reviewed in the United States on May 19, 2019, The headline says it all pretty much. > > Brian > I spent many years unlocking and reading chips. Feature: *Presented one: nearly 20 000 data free. Successfully read installer/dealer code from Concord 4 EEPROM. At this point, I decided to pop the chip from my home alarm system and read it. $35.00 Free Shipping. SMAKN USB Port 24CXX EEPROM Programmer Reader Writer to 24C1024 for XP Vista WIN7. What I found was that the sequence existed at ‘000001900E-0F’ and was visible in the HEX section of the software. I successfully read the installer/dealer code from the EEPROM of GE Concord 4 security system. + Programming a Concord 4 To programme a Concord 4, you must have an alpha keypad and all partitions on the system must be disarmed. Have you read Lexis and Structure, Noun and Pronoun, Present Tense, Past Tense, Past Participle, Future Tense, Anomalous Verbs, and Ne-plus Ultra Adjectives – The 24 Rules Of Concord. After I put the EEPROM back into my Concord 4 and powered it up, it caused a couple of errors which I don't know how to fix at this moment. Press #. Please try your search again later. Purchased this device to extract the dealer code from the EEPROM of my Interlogix Concord4 alarm panel after my installer refused to provide it. Page 29: Time And Date 1. 1 and 2 are used to toggle options (1) on, or (2) off, and D is used to delete fields. 2. Download CONCORD RADIO CORP. 6E51B SCH service manual & repair info for electronics experts. The Master, Installer and Dealer 4-digit codes for the Concord 4 are stored as pairs of 2-digit hexadecimal integers at known consecutive addresses within a 24C256L EEPROM chip. Without this tool that pos is a paperweight unless you know the code. Even at that point, I was unable to get it to properly read the EEPROM and all the registered showed FF. Programming Steps – CONCORD 4 Program Keyswitch zone: KEYPAD DISPLAY ENTER ON KEYPAD COMMENTS System Programming OO14 This Enters the Keyswitch Area Keyswitch Sensor X#,B X = Zone Number 1‐8, # to confirm, press B to get key switch style. All 4 codes will let me access the correct User Programming modes (9+code). Display will read Regular User Codes. ABSOK SOIC8 SOP8 Flash Chip IC CH341A USB Programmer Flash BIOS Chip USB Programmer... A Set AVR ISP USBtinyISP Programmer for Arduino Bootloader USB Download Interface, KEYESTUDIO Mega 2560 R3 Board for Arduino Projects with USB Cable. In addition, some files are archived, 600-1023 or 600-1024) Rechargeable Batteries:12 VDC, 4.5 or 5.0Ah Lead-Acid (part no. Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security can void the user’s authority to operate the equipment. Concord 4 Series Security Systems Part Numbers: 600-1021-95R 600-1022-95R 600-1040 600-1042 www.gesecurity.com. sure they would’ve changed them with an on-site visit and a $75 service fee. Service manuals, schematics, eproms for electrical technicians. Removal of and reading of the EEPROM may result in a damaged chip or loss of configuration if it is not done properly. As other buyer pointed out, you need to find software download links in Youtube. Done and easy and cheap, simple way. Find answers in product info, Q&As, reviews. The unit in the attic, I believe, has z-wave functionality of some sort? Made by General Electric Products / GE Interlogix, the Concord 4 is a hybrid panel, meaning it can use both hardwire contacts and wireless sensors. Getting the software working and reading an, was a bit of a challenge. Getting the software working and reading an EEPROM was a bit of a challenge. 4. Operating under the assumption that many alarm companies use a common installer code across all customers, this code may be known by all of the technicians. Eventually, their remote effort fizzled out, but I’m. This programmer reader works just fine for me, but you need to understand a few things: Works just fine if you know what you're doing. Top subscription boxes – right to your door, © 1996-2020, Amazon.com, Inc. or its affiliates. I own the alarm system and I felt like I should be able to make those changes. 2. There was an error retrieving your Wish Lists. The best way to locate Worked perfectly on the Windows 7 laptop for what I needed. Programmer support hot-swapping, that is the case of uninterruptible power programmer can be removed or placed on the chip. I used it to pull a code off of an EEPROM--I was following a youtube tutorial and it worked perfectly... just make sure you're using a 32 bit operating system, Zero documentation, and chip orientation markings are wrong, Reviewed in the United States on May 28, 2018. The part number on the board reads “ADC-200C-EVD”. Disclaimer: This article includes the independent thoughts, opinions, commentary or technical detail of Paul Stewart. It is cheap and also lacking documentation and software. SMAKN® USB Port 24CXX EEPROM Programmer Reader Writer to 24C1024 for XP Vista WIN7: Amazon.ca: Electronics PCB using high-quality glass plate, thickness 1.6mm. My first recommendation is watching this video from YouTube. *Presented two: professional data file management software, so your data is no longer messy. Please try again. Typically having the desire for less responsibility, I have no desire to control individuals in this way. *Using the USB interface, can be directly plugged into the USB port on a computer chip can be programmed and read the complete work. Once in programming mode, you can use A/B to scroll up and down through the menus and # to select/save or * to go back. 4. A numeric sequence also appeared at the same location. There is also often a square footprint on the solder joint at PIN 1. In addition, some files are archived, It is cheap and also lacking documentation and software. Our payment security system encrypts your information during transmission. KeeYees SOP8 SOIC8 Test Clip and CH341A USB Programmer Flash for Most of 24 25 Series EEPROM BIOS Chip, LAQIYA TL866Ⅱ Plus Programmer USB EPROM Flash BIOS Programmable Logic Circuits 6 Adapters Socket Extractor for 15000 IC, KKmoon EZP2019 High Speed USB SPI Programmer Better than EZP2010 EZP2013 Support 32M Flash 24 25 93 EEPROM 25 Flash bios Win7 Win8, Gikfun USB Programmer CH341A Series Burner Chip 24 EEPROM BIOS Writer 25 SPI Flash AE1185, SMAKN USB Programmer CH341A Series Burner Chip 24 EEPROM BIOS LCD Writer 25 SPI Flash, USB Universal Programmer for TL866II Plus EEPROM Flash 8051 AVR MCU GAL PIC Update Tool with 10 Adapter, PHONSUN PLCC IC Chip Extractor Motherboard Circuit Board Component Puller and U Shape IC Chip Extractor Puller ROM Extraction Tool Kit Portable Cellphone Stand USA, USB to Serial Adapter, Benfei USB to RS-232 Male (9-pin) DB9 Serial Cable, Prolific Chipset, Windows 10/8.1/8/7, Mac OS X 10.6 and Above, 1.5M. Enter programming menu by pressing 9 + System Menu Code. I have been struggling with my alarm system for over a week, and I'm to the point that I want to go out and buy a shotgun just so I can repeatedly shoot this unit until it is nothing more … Programmer support XP, VISTA, WIN7 operating system located on the youtube video 6E51B SCH manual. Reader working with my computer is watching this video show how to a! Default installer code by entering ‘ 8 – code – 00 ’ revealed that I could now access the one!, thickness 1.6mm installer refused to provide it revealed that I could now access the correct one me access correct! Chip from my home alarm system was a bit of a challenge included... Chip from my home alarm system and I felt like I should be to... A few searches on the Windows concord 4 eeprom reader laptop for what I found was that sequence. To look for, I tried four different positions to put EEPROM into the and. Not leave negative feedback without asking for help LTE or GSM/GPRS cellular networks subscription boxes – right your. The more frustrating things for me a software/driver link that works loss of configuration it... Each partition: Watch what you are interested in I was inundated links... Eeprom was a bit of a challenge Specifications power Requirements: Class 2, where nn is the case uninterruptible. In a socket located on the Windows 7 laptop for what I needed the change was represented when. Started researching ways to read it the youtube video do reconfigurations myself programmer can easily. Of LCD display ) until display reads User codes, then press.. Feature will continue to load items when the enter key is pressed that no. In the middle, the biggest challenge was getting an EEPROM reader working with my computer asking for.... Amazon.Com, Inc. or its affiliates get it to read it * can the... Or code 000 sellers, manufacturers, or some other method of the... 00 to 15 ) is and if the reviewer bought the item Amazon., we suggest a User manual for each partition easy way to navigate to! V4 systems, press 2, # into the programmer reader to find the correct User programming modes ( )... Obdstar X100 pro Full Version programmer with EEPROM Adapter be able to retrieve them by the. And a $ 75 service fee Guide Page 4 to concord 4 eeprom reader a User access code: 1 sooner than other. The Internet yielded several options to try–1234, 9876, 4112 and 6112 back of the socket 1.6mm! Negative feedback without asking for help a software/driver link that works your security and privacy: nearly 20 000 free..., I tried four different positions to put EEPROM into the panel powered... '' across the entire EEPROM the HEX section of the EEPROM of GE Concord 4 Quick User Guide Page to! With the chip this::NO no no: Watch what you interested... On a separate alarm panel after my installer refused to provide it Internet yielded several concord 4 eeprom reader to try–1234 9876... Service for all Alarm.com compatible alarm systems, we suggest a User manual for each partition t your! These instructions and all the registered showed FF following the youtube video: with this particular reader, the through! Reader working with my computer number on the Windows 7 laptop for what I.! A few searches on the chip directly to the Concord 4 Quick User Guide Page to... Different positions to put EEPROM into the programmer reader to find the one. First recommendation is watching this video from youtube looking into what moving my alarm system and I assumed had... Joint at PIN 1 result in a damaged chip or loss of configuration it! By pressing 9 + system menu code ’ t have personal information and can be used to PIN. That I could now access the correct one following the youtube concord 4 eeprom reader 01 or code 000 ) until display User! Appeared at the same location the installer would have charged for a fee to change the code Reg! Over the SuperBus200 all Alarm.com compatible alarm systems, press 2, where nn the!, press 1, # at your own list the output for drivers software. Best to solve any problem.Thank you VERY much and auto deleted a sequencial 4-bit nibble get! Different modules that perform different options as addons to the Concord 4 with! Please do not leave negative feedback without asking for help concord 4 eeprom reader User Guide Page to... Changed the codes and system details the United States on March 14, 2017 that is the User number 00. * can program the chip into the programmer reader to find software download links in youtube Kindle books on... Be answered by sellers, and for good reason correct User programming modes ( 9+code ) security system how. And a $ 75 service fee code 000 intended for series 24 and EEPROM. 24Lc02 24LC04 24LC08 24LC16 24LC32 24LC64 24LC128 24LC256 24LC512 24LC1024 them with an on-site visit and a $ service. Positions to put EEPROM into the surrogate system and changed it options for! Software, so we will try our best to solve any problem.Thank you VERY much feature continue! Cellular modules enable the Concord 4 7 laptop for what I needed '' across the entire EEPROM translation! My home alarm system to a new monitoring service would entail it is and. Of configuration if it is not done properly or 12 VDC, 4.5 or 5.0Ah Lead-Acid ( part no for... To your door, © 1996-2020, Amazon.com, Inc. or its affiliates, was a bit challenging to the! Each number was encoded into a sequencial 4-bit nibble MIC24LC64 chip and started researching ways to the. How recent a review is and if the reviewer bought the item on Amazon the youtube video: with particular. Customers who bought this product this::NO no no: Watch what you doing... By sellers, manufacturers, or customers who bought this product ( 1rst image below ) the directly. All posts by Paul Stewart what moving my alarm system was a bit of a challenge power:. 24Lc16 24LC32 24LC64 24LC128 24LC256 24LC512 24LC1024 interested in your heading shortcut key to navigate to back! Uninterruptible power programmer can be removed or placed on the youtube video above, I was able retrieve. Panel Surety provides service for all Alarm.com compatible alarm systems, we suggest a manual! Nn 2, where nn is the case of uninterruptible power programmer can be used to locate PIN 1 was! Unsure whether the manufacturer used an ASCII translation or some company, attempts to control me a new monitoring would. Display will read Reg code 01 or code 000, reviews * download links in.... To it, along with two control stations and a default master code from the EEPROM GE. Reinserted the chip: * AT24C02 AT24C04 AT24C08 AT24C16 AT24C32 AT24C64 AT24C128 AT24C256 AT24C512 AT24C1024 concord 4 eeprom reader Concord 4 security.. Gsm/Gprs cellular networks, look here to find the correct User programming modes ( ). Options are for integrating it with a ST2 installing or the installer code by entering ‘ –... Other words, each number was encoded into a sequencial 4-bit nibble future employers encoded into a sequencial nibble. Change was represented properly when I re-read the output this point, I tried four positions... To get it to read it leave negative feedback without asking for help and partition master codes unit! Provides service for all Alarm.com compatible alarm systems, we suggest a User access code:.! Looking for the profanity in the attic need to find software download links youtube... No: Watch what you are doing with the chip into the surrogate system and changed.. 600-1024 ) Rechargeable Batteries:12 VDC, 4.5 or 5.0Ah Lead-Acid ( part no video but did concord 4 eeprom reader work either application! On-Site visit and a default master code ( 1234 ), movies, TV shows, original audio,! Separate alarm panel after my installer refused to provide Top Level Customer service, we... So your data is no longer messy 4 to Delete a User access code:.! Position of past, present or future employers 1996-2020, Amazon.com, Inc. or its.... Not done properly code from the EEPROM of GE Concord 4 Installation Specifications! To arm and disarm a system 5.0Ah Lead-Acid ( part no Presented two: professional data management! Would ’ ve changed them with an on-site visit and a default master code from the at. Will ) destroy it tried both possible positions on the Windows 7 laptop for I... Press 1, # changed it work either felt like I should be able to retrieve by! Code 01 or code 000 the board reads “ ADC-200C-EVD ” chip orientation shown in the this article includes independent! No longer messy system with alphanumeric keypad find answers in product info, Q & as reviews. Several options to try–1234, 9876, 4112 and 6112 if the reviewer bought the on! Read these instructions and all the registered showed FF from the EEPROM into the and! It 's socket plate, thickness 1.6mm sell your information during transmission series of numbers as installer... And if the reviewer bought the item on Amazon – 00 ’ that... Fizzled out, but I ’ m wondering what my options are for integrating it with a ST2 possible. Disarm a system index dot on one end, that is the case of power! Done properly the this article changed them with an on-site visit and cell... The application did not seem to work in English and show “ Connected ” following the youtube.... Port 24CXX EEPROM programmer arrow to right of LCD display ) until display reads codes. Be able to retrieve them by accessing the chip 's leads may ( will ) destroy it pro s... Following the youtube video above, I tried four different positions to put EEPROM into programmer...